Description | Tests manually-fed PCBs and low and high temperatures. |
Minimum temperature | - 30°C |
Maximum temperature | 100°C |
Chamber | Flat type |
Refrigeration | Integrated |
Dimensions | Width: 855 mm, Depth: 1737.5 mm, Height: 1260 mm |
Description | Continuously tests pieces fed from pallets 4 at a time by cooling and heating, removes defective parts, and feeds remaining pieces on to the next process. |
Minimum temperature | - 40°C |
Maximum temperature | 100°C |
Chamber | Elevator type |
Refrigeration | Two air-cooled AI-860 models |
Dimensions |
Width: 1920 mm, Depth: 3390 mm, Height: 1881 mm (sampler, refrigeration unit, air dryer, and heater separate) |
Description | Continuously tests pieces fed from pallets 4 at a time by cooling and heating, removes defective parts,and feeds remaining pieces on to the next process. |
Minimum temperature | -30°C |
Maximum temperature | 80°C |
Chamber | Flat type |
Refrigeration | Three water-cooled AI-870 models |
Dimensions |
Width: 1200 mm, Depth: 10520 mm, Height: 1705 mm (sampler, refrigeration unit, air dryer, heater, and spot cooler separate) |
Description |
Demonstration model. Makes use of transport systems like tray changer and pick-and-place units, linear conveyors,spike conveyors, and vertical index sock-plates. Ample space is provided around the contacts to accommodate existing test heads, which can be customized to suit the customer’s specifications. |
Minimum temperature | -65°C |
Maximum temperature | 150°C |
Chamber | Flat type |
Refrigeration | Integrated |
Dimensions | Width: 1660 mm, Depth: 1300 mm, Height: 1600 mm |
Description |
Holds a piece previously cooled to -40°C in a 125°C chamber for 60 minutes and runs an electrical current through it. Since the chamber resembles a Japanese shoe-rack, the unit is referred to as the “shoe rack” edger. |
Minimum temperature | -40°C |
Maximum temperature | 125°C | Refrigeration | Shoe-rack type |
Dimensions |
Width: 1600 mm, Depth: 1500 mm, Height: 1500 mm (1925 mm when projected) (sampler separate) |